Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Gan To Kagaku Ryoho ; 51(2): 202-204, 2024 Feb.
Artigo em Japonês | MEDLINE | ID: mdl-38449413

RESUMO

Eighty-one year-old woman was pointed out pulmonary tumor by health check and transferred to our hospital. Her performance status was fine. In imaging study, she had advanced gastric cancer with a solitary liver metastasis and highly suspected left lung cancer. She received chemotherapy combined with oxaliplatin and S-1 as first-line. However, the tumor enlarged and then received second-line chemotherapy combined with paclitaxel and ramucirumab. The tumor shrank and a solitary liver metastasis remained. She underwent gastrectomy and partial hepatectomy. After conversion surgery, she had no chemotherapy and had survived over 5 years. Even in old person over 80 years old, chemotherapy and surgery are considerable in patients with well performance status.


Assuntos
Neoplasias Hepáticas , Neoplasias Pulmonares , Neoplasias Gástricas , Humanos , Feminino , Idoso de 80 Anos ou mais , Neoplasias Gástricas/tratamento farmacológico , Neoplasias Gástricas/cirurgia , Neoplasias Hepáticas/tratamento farmacológico , Neoplasias Hepáticas/cirurgia , Ramucirumab , Gastrectomia
2.
J Appl Clin Med Phys ; 24(5): e13971, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36951306

RESUMO

BACKGROUND: There are some motion platforms for radiotherapy quality assurance. However, no platform with two drive systems that can move along three axes is available. PURPOSE: The purpose of this study is to develop a dynamic motion platform with two drive systems capable of three-axis motion and to evaluate its motion performance. METHODS: The developed moving platform had two drive systems that use the same equipment. Each axis of the platform used can support a maximum load of 10 kg. The motors for moving the platform in each direction are capable of a drive stroke up to 40 mm. The drive speed is 30 mm/s at maximum load fluctuation. To evaluate the static positional accuracy of this system with an arbitrary input movement, the XYZ position of each axis was measured using a coordinate measuring machine operating from 0 to 40 mm at 10 mm intervals. In addition, the accuracy of dynamic motion was verified with Sine waveform inputs of different patterns to the three axes for approximately 60 s, and they were compared with the resulting detected signals by SyncTrax. RESULTS: The two drive systems were successfully operated on three axes by using independent control systems. For static position, the accuracies were within 0.2 mm, 0.05 mm, and 0.14 mm for lateral, longitudinal, and vertical directions, respectively. For dynamic motion, the mean absolute errors in the X, Y, and Z axes between the platform inputs and SyncTrax detected signals were 0.14 ± 0.10 mm, 0.16 ± 0.12 mm, and 0.16 ± 0.11 mm, respectively. CONCLUSIONS: A new dynamic platform for radiation therapy with two drive systems capable of three-axis motion was developed, and the positional accuracy of the drive axes was confirmed to be less than 0.2 mm.


Assuntos
Movimento , Humanos , Imagens de Fantasmas , Movimento (Física)
3.
Clin J Gastroenterol ; 15(3): 553-559, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35352238

RESUMO

The celiac artery usually trifurcates into the common hepatic artery, splenic artery, and left gastric artery, but it is known to present several anatomical variations. In such cases, detailed knowledge of the variation is needed preoperatively to safely perform surgery. A 77-year-old woman was referred to our hospital for the treatment of gastric cancer. She had a triple anatomical variation: simultaneous presence of the hepato-spleno-mesenteric trunk, a common trunk for both inferior phrenic arteries and the left gastric artery, and a common hepatic artery that ran behind the portal vein. We detected this variation on routine preoperative multidetector computed tomography angiography, and safely and adequately performed laparoscopic distal gastrectomy.


Assuntos
Artéria Gástrica , Neoplasias Gástricas , Idoso , Aorta Abdominal , Feminino , Artéria Hepática/diagnóstico por imagem , Artéria Hepática/cirurgia , Humanos , Veia Porta/diagnóstico por imagem , Neoplasias Gástricas/complicações , Neoplasias Gástricas/diagnóstico por imagem , Neoplasias Gástricas/cirurgia
4.
Gan To Kagaku Ryoho ; 48(13): 1969-1971, 2021 Dec.
Artigo em Japonês | MEDLINE | ID: mdl-35045463

RESUMO

We have experienced 3 cases of solitary brain metastasis after radical surgery in advanced gastric cancer. All of them have similar characteristics such as, upper third location, solitary metastasis to the cerebellum, and no other organ metastasis. As there is a risk of brain hernia, resection have been underwent first, and radiotherapy administered after surgery. One case has been provided over 2-year survival.


Assuntos
Neoplasias Encefálicas , Neoplasias Gástricas , Neoplasias Encefálicas/cirurgia , Gastrectomia , Humanos , Neoplasias Gástricas/cirurgia
5.
Gan To Kagaku Ryoho ; 47(2): 331-333, 2020 Feb.
Artigo em Japonês | MEDLINE | ID: mdl-32381979

RESUMO

A 73-year-old man was admitted with the chief complaint of upper abdominal discomfort.After close examination, he was diagnosed with a huge stomach gastrointestinal stromal tumor(GIST)that occupied the upper left abdomen with a maximum diameter of 150 mm.The patient was referred to our department for surgery.The border between the tumor and spleen was unclear on CT images.As the diaphragm was thinned due to compression by the tumor, gastrectomy with splenectomy and partial resection of the diaphragm was planned.For the diaphragmatic defects, a simple closure was considered at first. However, artifacts have a high risk of infection when the defect holes are too large.Therefore, in this case, we attempted to repair the diaphragm hole with the autologous fascia lata.Intraoperatively, while the tumor was resected with 1 more layer of the diaphragm, the diaphragm itself was thinned, resulting in a defect hole of about 60×80 mm.Therefore, an 80×110mm fascia lata was harvested, and the diaphragm was repaired.Fascia lata can be conveniently harvested as a free graft.In addition, the fascia of the thigh has the advantage of being more resistant to infection than artificial materials.In addition, there was no functional failure due to collection, and special plastic surgery techniques and tools were unnecessary.Thus, it is a useful reconstruction material for general surgeons.Here we report the details of the surgery along with a review of the literature.


Assuntos
Neoplasias Gastrointestinais , Tumores do Estroma Gastrointestinal , Procedimentos de Cirurgia Plástica , Idoso , Diafragma , Fascia Lata , Gastrectomia , Neoplasias Gastrointestinais/cirurgia , Tumores do Estroma Gastrointestinal/cirurgia , Humanos , Masculino
6.
Clin Case Rep ; 5(5): 654-657, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28469870

RESUMO

Retroperitoneal perforation of duodenal diverticula around the papilla of Vater is relatively rare. In this report, we describe retroperitoneal abscess, which was successfully treated by endoscopic drainage. Thus, endoscopic approach for retroperitoneal perforation caused by diverticulum is one of the treatment options in addition to surgery.

7.
Radiology ; 255(3): 917-23, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20501729

RESUMO

PURPOSE: To evaluate the use, structural principles, operation, and acquired reproducibility of a respiratory monitoring device to be used for voluntary patient breath holding. MATERIALS AND METHODS: Evaluation was performed of a respiratory monitoring device that enables determination of the respiratory level in a patient by measuring the movement of two contacts on the abdomen and chest wall. Neither metallic nor electronic materials are used in the mechanics for this device. The initial study group comprised 21 consecutive patients (15 men, six women; mean age, 75 years; range, 56-92 years) with lung or abdominal tumors who underwent examination with the device and computed tomography (CT) for three-dimensional reproducibility of lung base position during voluntary breath holding with or without use of the device. RESULTS: One patient with mild dementia was excluded; in most of the remaining 20 patients, high reproducibility of the breath-holding position was achieved in a short time with the device. In these 20 patients who were able to adapt to use of the device, three-dimensional mean maximum differences in lung base position during three random voluntary breath holds were 2.0 mm along the cranial-caudal axis, 1.5 mm along the anterior-posterior axis, and 1.2 mm along the right-left axis. The differences in all axes were significantly smaller with use of the respiratory monitoring device than without the device. CONCLUSION: The device demonstrates satisfactory reproducibility of voluntary patient breath holding easily and inexpensively and may offer a convenient device for easy use during irradiation with voluntary breath-holding conditions that require a small internal margin.


Assuntos
Neoplasias Abdominais/diagnóstico por imagem , Neoplasias Abdominais/radioterapia , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Monitorização Fisiológica/instrumentação , Tomografia Computadorizada por Raios X , Abdome/fisiologia , Idoso , Idoso de 80 Anos ou mais , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Movimento , Postura/fisiologia , Reprodutibilidade dos Testes , Respiração , Parede Torácica/fisiologia , Imagem Corporal Total
8.
Med Phys ; 32(7): 2231-5, 2005 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16121577

RESUMO

A packed building-block compensator (TETRIS-RT) for IMRT (Intensity Modulated Radiation Therapy) delivery has been proposed. The compensator contains two kinds of cubic blocks: x-ray absorbing blocks for intensity modulation and x-ray transparent blocks for packing. The packed blocks are placed inside a rectangular enclosure, and the resulting compensators can be attached to a linac gantry head through a rotatable mount for efficient multiportal IMRT. A fabrication device and a sorting device were also developed. The fabrication device can automatically stack two different types of blocks to produce a compensator while the sorting device can separate each type of the blocks for subsequent fabrication. Preliminary film experiments have shown that an additional leakage dose through the rounded edges of the ten-layered x-ray absorbing blocks was 0.9% of the delivered dose with a total shielded dose ratio of 10% including the peak leakage. It was observed that the proposed compensator may provide a highly modulated dose distribution. This suggests its feasibility for IMRT delivery with a limit of 1 cm x 1 cm spatial resolution at isocenter in the plane perpendicular to the beam, and larger discrete intensity steps of approximately 10% compared to conventional compensators. Advantages of the proposed compensator include that the compensator blocks are reusable and can be utilized to automatically and quickly fabricate a compensator, thereby minimizing human labor.


Assuntos
Materiais de Construção , Dosimetria Fotográfica , Radioterapia Conformacional/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Estudos de Viabilidade , Dosagem Radioterapêutica , Radioterapia Conformacional/métodos
9.
Med Phys ; 32(7Part1): 2231-2235, 2005 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28493568

RESUMO

A packed building-block compensator (TETRIS-RT) for IMRT (Intensity Modulated Radiation Therapy) delivery has been proposed. The compensator contains two kinds of cubic blocks: x-ray absorbing blocks for intensity modulation and x-ray transparent blocks for packing. The packed blocks are placed inside a rectangular enclosure, and the resulting compensators can be attached to a linac gantry head through a rotatable mount for efficient multiportal IMRT. A fabrication device and a sorting device were also developed. The fabrication device can automatically stack two different types of blocks to produce a compensator while the sorting device can separate each type of the blocks for subsequent fabrication. Preliminary film experiments have shown that an additional leakage dose through the rounded edges of the ten-layered x-ray absorbing blocks was 0.9% of the delivered dose with a total shielded dose ratio of 10% including the peak leakage. It was observed that the proposed compensator may provide a highly modulated dose distribution. This suggests its feasibility for IMRT delivery with a limit of 1cm×1cm spatial resolution at isocenter in the plane perpendicular to the beam, and larger discrete intensity steps of approximately 10% compared to conventional compensators. Advantages of the proposed compensator include that the compensator blocks are reusable and can be utilized to automatically and quickly fabricate a compensator, thereby minimizing human labor.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA